04.10.20 KAWEFLEX® 6430 SK-C-PUR UL/CSA, low capacity

Application

Shielded electronic cable for data and signal transmission for high mechanical requirements in drag chains, in electrical motion facilities, machine tools and handling automats.

Special Features

  • UL/CSA approved
  • low adhesion, silicone-free
  • UV-resistant
  • halogen free, flame-retardant acc. to IEC 60332-1-2, FT1, VW1
  • oilresistant acc. to DIN EN 60811-404
  • largely resistant to grease, coolant fluids and lubricants
  • recommended for EMC-compatible applications

Remarks

  • conform to RoHS
  • conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
  • cables for torsional stress see chapter 04.25
  • We are pleased to produce special versions, other dimensions, core and jacket colours on request.

Structure & Specifications

conductor_material bare copper strand
conductor_class super fine wires acc.to VDE 0295 cl. 6 pt. 4 resp. IEC60228 cl. 6 pt. 4
insulation_material PELON®2
wire_identification coloured acc. to DIN 47100
shielding_total copper braid tinned, coverage approx. 85% ± 5%
twisting_total cores stranded in layers
outersheath_material PUR
sheath_color grey RAL 7001
voltage_nominal acc. to VDE: 300/300V; acc. to UL: 300 V
voltage_test core/core: 1.500 V; core/shield: 500 V
resistance_conductor at +20 °C acc. to DIN VDE 0295 cl.6 resp. IEC60228 cl.6
resistance_isolation at +20 °C ≥ 500 MΩ x km
carrying_capacity acc. to DIN VDE
capacity core/core: approx. ca. 65 pF/m
inductance approx. 0,6 mH/km
bending_radius_smallest_fixed 5 x d
bending_radius_smallest_moving 7,5 x d < 10 m TL; 10 x d ≥ 10 m TL
operating_temperature_fixed -50 °C / +80 °C
operating_temperature_moving -40 °C / +80 °C
fire_behaviour flame-retardant acc. to IEC 60332-1-2, FT1, VW1
oil_resistance acc. to DIN EN 60811-2-1
approbation UL/CSA - cURus 300V, 80°C
traversing_speed self-supporting: max. 10 m/s, gliding: max. 5 m/s
traversing_way max. 50 m
acceleration max. 20 m/s²

Downlaod Datasheet Download certificate

To top